320. The JH7110 clock and reset wire: device-level verbs, and the badge is the device
(Section number provisional until the merge queue lands it. Every name below is provisional under design/naming.md; the wire is not.)
Background
The JH7110 powers most of its blocks off at reset. Before a driver can touch the TRNG, the GMAC, an
SD/MMC controller or the I2C bus to the power chip, something sets an enable bit in that block's
clock words and clears its bit in a reset word. Those words sit in shared 64 KiB windows, one per
domain: STG at 0x1023_0000, SYS at 0x1302_0000 and AON at 0x1700_0000. Reset bits pack 32 to
a word, so releasing one block's reset is a read-modify-write of a word that holds 31 others.
Today the kernel does it. kernel/src/drivers/jh7110_clock_and_reset.rs (193 lines, 120 of code)
walks plans that crates/jh7110_clock_and_reset supplies, for five callers: the entropy starter,
the GMAC bring-up, the SD/MMC starter and its card clock, the reboot path's I2C5, and the soak's
watchdog. Nothing in the tree turns a clock off or asserts a reset. §304 (who may turn a device off)
keeps it so until a bench run measures the power cost.
Milestone 1062 (the device control planes leave the kernel) moves this to a userspace server whose
verbs live in a contract crate both sides use (§311 (a contract is code, not prose)). Its steps 3
and 5 depend on that server. The wire must fit three fixed facts. A CALL carries two words and its
reply two (§12 (call and reply IPC)). The server learns the caller by a badge the kernel stamps
once (§230 (badged endpoint capabilities)). And a server scopes each client by that badge, never by
an id the client wrote (§256 (a server that keeps windows for many clients scopes each by the caller's badge)).
The decision
Device-level verbs, and the badge is the device. The starter that grants a driver its device's
register pages also mints a badged copy of the server's endpoint. The badge is that device's
register base physical address, as the device tree's reg gives it: 0x1603_0000 for the GMAC's
first port, 0x1600_c000 for the TRNG. The server maps the badge to that device's clocks and
resets and to nothing else. No request word names a device, so §256 holds by construction.
The wire is interface id 24, version 1, with no magic. A magic marks offset 0 of a shared page, and
this contract has no page; entropy_contract and socket_contract carry none either.
The opcode sits in bits 63:56 of request word 0, where entropy_contract::OPERATION_SHIFT puts it.
| opcode | verb | arguments | reply word 1 |
|---|---|---|---|
| 0 | version query, reserved | none | the served versions, as milestone 1000 (message contracts carry bind-time version checks) defines them |
| 1 | bring up | none | the bring-up summary |
| 2 | read clock | word 0 bits 7:0, the device's own clock index | that clock's raw word |
| 3 | read reset | word 0 bits 7:0, the device's own reset index | that reset's own status bit: 1 released, 0 held |
| 4 | set rate | word 1, the most hertz the device may run at | the hertz it now runs at |
Opcodes 5 to 255 are free. No verb turns a device off.
A request sets only the bits its opcode gives a meaning. Word 0 bits 55:8 are always zero, the index is zero except for opcodes 2 and 3, and word 1 is zero except for opcode 4. The server answers anything else with status 8 and reads or stores nothing, so an undefined bit never reaches the silicon, and a later version can give it a meaning. The checks run in a fixed order: the badge (status 1), then the opcode (status 2), then the shape (status 8). A read-reset reply carries only the device's own line, because the other 31 lines of its status word belong to other devices.
Bring up walks the device's clocks, each parent choice before its clock's enable, then its resets, in the crate's plan order. It is idempotent, since firmware may have started the block, so a client whose call failed simply calls again. Set rate serves the one rated clock a caller sets today, the SD/MMC card clock; the server refuses it for a device with none.
Reply word 0 is a status, a small non-negative number. A kernel failure of the CALL itself is a
small negative, enormous as a u64, so the two never collide (entropy_contract::delivered's
reasoning).
| status | meaning |
|---|---|
| 0 | done |
| 1 | the badge names no device this server serves, badge 0 included |
| 2 | an opcode this server does not serve |
| 3 | an enable bit did not read back set |
| 4 | a reset did not read released within the poll bound |
| 5 | a read named a clock or reset beyond the device's own |
| 6 | set rate on a device with no rated clock |
| 7 | no divider gives a rate at or below the one asked |
| 8 | malformed request: a bit its opcode gives no meaning is set |
For statuses 3 and 4 the server still sends the summary, so the failure is diagnosable. A bring-up whose clock did not run answers 3 even if a reset also stayed held: the plan enables every clock before it releases any reset, and a reset behind a gated clock may never release. A refused step is counted in the summary and changes no status.
The bring-up summary, from bit 0: bits 7:0 count the clocks the plan enables, 15:8 those reading back as running, 23:16 the resets in the plan, 31:24 those released. Bit 32 says the device was already up before the call. Bits 47:40 count steps the server refused. The rest is zero.
Why A. It has the fewest moving parts. The order the silicon needs stays in one place, the server, where host tests already pin it. It needs no refcount, since nothing releases twice or turns off, and it obeys §304 by having no off verb. And it is the restrictive choice. nife means its drivers to be portable across many chips, so line-level verbs may come later. They arrive as new opcodes with no version bump, while taking one back would be a break.
The options refused
- B, line-level verbs by the device tree's
clock-namesandreset-names. Every client would carry the order the silicon needs, and any later off verb would need a per-line refcount. Refused for today; it can arrive later as new opcodes. - C, a plan the client uploads. A list of steps does not fit two words, so it needs a shared page and a magic, and the server would check the client's order anyway.
Prior art
- OpenBSD, read (
sys/dev/ofw/ofw_clock.c, revision 1.11). The kernel's FDT drivers callclock_enable(node, name),clock_set_frequency,reset_deassert(node, name)andclock_set_assigned(node), resolving each name through the node'sclock-namesorreset-names. Whole-device forms exist too (clock_enable_all,reset_deassert_all). There is no refcount. Each driver carries its own order:dwqe_fdt_attachenables two clocks, deasserts both resets, then enables two more. That is B's shape, run in the kernel and trusted. - FreeBSD extres, recalled.
clk_get_by_ofw_name,clk_enableandhwreset_get_by_ofw_namename a line by the node and its name, with enables counted up the parent tree. Also B's shape, in the kernel. - NetBSD fdtbus, recalled.
fdtbus_clock_getandfdtbus_reset_getby name, thenclk_enableandfdtbus_reset_deassert. B's shape again. - Genode's platform driver, recalled. One userspace process owns the devices. A client acquires a device by name as its policy allows, and the platform driver switches on that device's power, resets and clocks as its description lists them. The client calls no clock verb. This is A's shape and the closest precedent.
Where nife differs: the verbs cross a process boundary; the kernel-stamped badge names the device, never a client-written id; the order is the server's, where the BSDs leave it to each driver; and nothing turns off, so nothing needs counting.
A concrete example. The progenitor starts the server with the STG, SYS and AON windows. To start
the GMAC's control process it badges the server's endpoint with 0x1603_0000 and calls opcode 1.
The server enables SYS clocks 108, 111 and 109 and AON clocks 3 and 2, chooses parent 1 for AON
clock 5 while its gate is still shut, enables clock 5, and releases AON resets 0 and 1. It replies status 0
with a summary of six clocks enabled and running and two resets released. A read of clock 9 on that
capability answers status 5, and nothing it can send reaches the TRNG's clocks in STG.
What is one-way
Once a peer outside the tree builds against the wire, these hold for good:
- interface id 24, and what version 1 means;
- the opcode numbers, opcode 0's reservation for the version query, and where each argument sits;
- the status codes, and the layout of reply word 1 for each opcode, the summary included;
- that the badge is the device's register base physical address, the agreement between every starter and the server; a second scheme would give one badge two live meanings.
That no verb turns a device off is not one-way: an off verb is a new opcode, and a version 1 client never relied on its absence.
Two-way: every name, the crate's and the program's included, and any new opcode. So are whether the starter or the driver holds the capability, and whether the server takes a device's plan from the crate or the tree. The readiness word, the poll bound and the restart policy are two-way too.