roadmap REFUSED

224. Nothing can power-cycle radon, so a hung soak needs a person

Refused by calef on 2026-09-04 (UTC). With the four options below in front of him and the diagnosis re-measured, calef chose manual power. Milestone 257 (boot radon over the network) is what made that the cheaper answer: it took away the card, which was the larger cost of a bench session, and left remote power buying only the hung-board case. This is the soak's remaining gap after milestone 221 (the soak never crosses cores, so build the hook that makes it).

Every option left below needs a person at the router or at the outlet, in the second sense of HARDWARE that notes/roadmap.md names, the one that never discharges by waiting. Reading the access point's configuration, moving the board's outlet, putting patagonia's radio on the plug's network and writing one firewall rule are all hands rather than decisions, and no lane can do any of them.

In brief. radon's power is on a Kasa KP303 strip. calef wired it on 2026-09-01, and outlet 2 is the board while another outlet feeds an external drive that must never be switched off. python-kasa and a vf2-power wrapper are installed on patagonia, and the wrapper addresses the board's outlet by alias with no way for a caller to name a different one. An index is right until a firmware update reorders the children.

None of it can reach the plug. Measured on 2026-09-01 from both patagonia and cordoba, by broadcast and by unicast to every host on the subnet, with both the legacy and the newer discovery protocols: zero replies. ARP for the plug's address is incomplete from wired and wireless alike, while five other clients on the same subnet answer normally. The vendor app controls it, which it can do through the vendor's cloud.

So the plug is deliberately isolated from other clients on the network it is joined to.

Revisit

Why it matters now rather than as a convenience

Fatal risk 5 (it cannot be made reliable on multicore, and the bugs appear only on silicon) wants sustained runs, and after milestone 221 there are two experiments to sustain rather than one. A soak that never crashes needs no power cycle, so this does not block a first run. A soak that hangs is exactly the outcome the experiment exists to produce, and that outcome currently ends with a board sitting hung until somebody walks to it.

script/board-console reads and never writes, so a boot that lands at U-Boot's prompt cannot be rescued either.

The options, none chosen, and the first is not free

Re-measured 2026-09-04, and the diagnosis got sharper

The 2026-09-01 finding reproduces exactly. From patagonia, on the evening radon was first put on ethernet: zero Kasa replies, by broadcast on both of patagonia's interfaces and by unicast to all 254 addresses on the subnet, using the legacy port-9999 protocol. The plug is not reachable and this is not a transient.

Two facts this block did not have.

The subnet is 192.168.8.0/24 and the gateway is 94:83:c4:be:26:de at 192.168.8.1, which is GL.iNet. That address is GL.iNet's factory default LAN and their guest network is isolated by design, so "client isolation" stops being an inference from a symptom and becomes a named feature of a specific product. Nobody has still read the configuration, so the BUGS entry below stands, but the guess is now a much better one.

patagonia is already dual-homed, and the second interface is redundant. en0 is Wi-Fi (192.168.8.216) and en9 is a USB ethernet adapter (192.168.8.206), both on the same subnet. Kasa plugs are Wi-Fi only, so the plug is on some SSID this machine is not on.

Two options this block did not list, recorded for whoever revisits it

Both are cheaper than the network-wide toggle this block declined to recommend, and neither was available to it because both depend on the two facts above.

Why it was still declined, and this is the honest version

Not because the options are bad. calef chose manual power on 2026-09-04 with all four in front of him. What changed the calculus that evening is that milestone 257 removed the larger tax: the card, not the power button, was what made a bench session expensive, and network boot takes that away without touching anyone's network. Remote power buys the hung board case, which fatal risk 5's soak produces and ordinary work does not.

So the cost of staying manual is now narrower than this block priced it, and it is still exactly what this block said: an evening every time the soak produces its most interesting result.

BUGS

Index row

calef chose manual power 2026-09-04 after the diagnosis was re-measured: still zero Kasa replies from either of patagonia's interfaces, and the gateway is GL.iNet, whose guest network isolates by design. Milestone 257 removed the larger tax (the card), so staying manual costs less than this block first priced it