radon's boot lottery: the rebooting soak's draws
Name: provisional.
An appendix to notes/soak.md, for milestone 249 (the boot lottery is sampled by a
person walking to the board). It holds the distribution that milestone's proof asks for, read off
the captures already in bench/, beside the nine hand-drawn boots in
rebooting-soak.md.
The count
129 unattended draws, against the fifty the proof asks for. 52 of them are one series on one build, the 2026-10-22 capture, which passes fifty alone.
A draw counts here when it ran the rebooting soak (script/board-image --soak --reboot) and its
boot began from the previous draw's own reset, with nobody at the board. Two kinds of boot are left
out, and both are in the table below so the count can be checked:
- The first boot of each capture, which did not begin from a reset in the capture. On 2026-10-20 and 2026-10-21 the record says calef powered radon on for it. There are four. A power-on is the hand-drawn experiment, not this one. The 2026-10-21 PMIC-report and 2026-10-22 captures begin mid-series, so every draw in them followed a reset and counts.
- Row E6, the second boot in
soak-boot2.log. It began from E5's reset with nobody there, but it booted the plain soak image for a ten-hour run, not the rebooting soak. The tally reads it as a draw (one clean core, 178,629/s) and this count does not.
Every number here is script/board-console --tally run over the cleaned capture, unedited. The
tally read all seven files; nothing was counted by hand.
| capture | build | draws | of them unattended | 1 clean core | 2 clean cores |
|---|---|---|---|---|---|
bench/radon-2026-10-10/soak-boot2.log |
bef2b40dc |
2 | 0 (draw 2 is E6) | 1 | 1 |
bench/radon-2026-10-10/592-optionb-four-cycles.log |
23f0c8d87 |
5 | 4 (draws 2 to 5) | 2 | 3 |
bench/radon-2026-10-20/soak-reboot-draws.log |
22c19e1d5 |
13 | 12 (draws 2 to 13) | 13 | 0 |
bench/radon-2026-10-21/soak-reboot-draws.log |
cda4ceb55 |
25 | 24 (draws 2 to 25) | 25 | 0 |
bench/radon-2026-10-21/soak-stop.log |
cda4ceb55 |
1 | 1 (draw 26) | 1 | 0 |
bench/radon-2026-10-21/225-pmic-report-draws.log |
0e0866d93 |
36 | 36 | 35 | 0 |
bench/radon-2026-10-22/249-lottery-draws.log |
80fd9428c |
52 | 52 | 46 | 0 |
The PMIC-report capture also drew zero clean cores once, and the 2026-10-22 one six times; the last two columns count only one and two.
The distribution of the 129 unattended draws:
| clean cores | draws | rates seen |
|---|---|---|
| 0 | 7 | 30,856 to 30,858/s |
| 1 | 119 | 177,520 to 206,734/s |
| 2 | 3 | 317,194 to 318,796/s |
| 3 | 0 | |
| 4 | 0 |
Three and four clean cores have never been drawn, by hand or unattended. Zero has been drawn only by the two latest builds, 7 times in 88.
The six zero-clean-core draws of 2026-10-22 settle into two arrangements, both with a grinder on every core that holds a pair (draws 18, 44 and 47 of 2026-10-22 one way; 29, 37 and 38 the other). Their rates agree to within 2 per second, and their crossings froze at 20 to 28 from the first beat, so they are among milestone 225's "not crossing" draws.
What each number means, and where it is not comparable
- A count of draws is not a probability. The tally prints this beside every table, and it holds here twice over, because the 129 come from six builds.
- The builds do not look alike. The two 2026-10-10 builds drew two clean cores on 4 of their 6 rebooting-soak boots. The four later builds drew two clean cores on none of their 125 unattended draws, and zero on 7. Pooling them into one distribution hides that split, so the per-capture table is the one to read. This page does not say why; why a placement lands where it does is DECISIONS 138's question, and no quantity of draws answers it.
- The nine hand-drawn boots are not the same experiment. They were power cycles on a 2026-09-03
build and drew two clean cores six times. These are warm resets through the AXP15060 write
(milestone 592 (radon's cold reboot dies in OpenSBI's PMIC write)), which hold firmware state
constant in a way a power cycle does not (249's
BUGS). - Rate is IPC throughput, not crossings. A draw at 1 clean core and about 190,000/s can hold 17
crossings or 27,000; the crossing count is a column of milestone 225 (run the soak on radon,
argon and xenon), in
../multicore-defect-curve/radon-rows.md. - The 2026-10-22 build arms the JH7110 watchdog on every draw (milestone 593 (a wedged kernel resets itself)), which the earlier builds did not. No draw was reset by it.
- The last draw of each of the two newest captures is read at fewer beats: 2026-10-22's draw 52 was disarmed by hand at t=65 s and left soaking, and the PMIC-report capture ends at t=35 s.
- Draw 26 was read at one beat.
--stopdisarmed it then and it was left soaking, so its row is the boot census and one rate, not 120 seconds. - The
endedcolumn misreads one draw. Draw 2 of 2026-10-21 reset itself at about t=105 s without the kernel's reset lines, and the tally reports it aslog ends herealthough the capture continues into draw 3. The reset is milestone 225'sBUGS; the draw's placement and rate are read normally. - Draw 25 of 2026-10-21 is split across two files at beat 20, by the port handover to
--stop; it is one draw, counted once.
What more draws would answer
Fifty is met, so further draws buy resolution rather than the proof: how rare two clean cores are on the current builds, and whether zero stays near one in eight. A series on one build is worth more than scattered draws, since the build split above is the open question.